Geil Front Loading, Fiber Lined, Natural Draft Kilns


Home » Kilns & Firing Accessories » Geil Gas Kilns » Geil Front Loading, Fiber Lined, Natural Draft Kilns

 Checkout
Geil  802 Natural Draft Kiln - Natural Gas

Details 

Temperature Range is 0-2400F. 4 burners. 130,000 BTU. Maximum Gas Consumption is 118 CFM. Minmum Gas Pressure is 4 inches water column. Gas line inlet is 1/2". Inside volume is 11 cubic ft. Setting Space is 8 cubic ft. Inside Dimensions are 25"w x 22"d x 35"h. Uses 2-10" x 20" or 1-20" x 20" shelves per layer. Outside Dimensions are 35"w x 40"d x 59"h. Electronic flame safety, 100% Shut Off. Push button automatic spark ignition. Manual control valve. 0-15" water column pressure gauge. DD-1 digital, solid state, electronic controller which functions as a high-limit, on/off soaking controller. ETL (InterTek) Certified. Ship wt. is 633 lbs.
Price: Price: Please call

 

Details 

Temperature Range is 0-2500F. 4 burners. 100,000 BTU. Maximum Gas Consumption is 91 CFM. Minmum Gas Pressure is 6 inches water column. Gas line inlet is 3/4". Inside volume is 12 cubic ft. Setting Space is 8 cubic ft. Inside Dimensions are 27"w x 23"d x 33"h. Uses 2-10" x 20" or 1-20" x 20" shelves per layer. Outside Dimensions are 43"w x 50"d x 61"h. Electronic flame safety, 100% Shut Off. Push button automatic spark ignition. Manual control valve. 0-15" water column pressure gauge. DD-1 digital, solid state, electronic controller which functions as a high-limit, on/off soaking controller. ETL (InterTek) Certified. Ship wt. is 1450 lbs.
Price: Price: Please call

 

Details 

Temperature Range is 0-2500F. 6 burners. 200,000 BTU. Maximum Gas Consumption is 136 CFM. Minmum Gas Pressure is 6 inches water column. Gas line inlet is 3/4". Inside volume is 17 cubic ft. Setting Space is 12 cubic ft. Inside Dimensions are 31"w x 27"d x 36"h. Uses 2-12" x 24" shelves per layer. Outside Dimensions are 47"w x 53"d x 66"h. Electronic flame safety, 100% Shut Off. Push button automatic spark ignition. Manual control valve. 0-15" water column pressure gauge. DD-1 digital, solid state, electronic controller which functions as a high-limit, on/off soaking controller. ETL (InterTek) Certified. Ship wt. is 1600 lbs.
Price: Price: Please call

 

Details 

Temperature Range is 0-2500F. 6 burners. 200,000 BTU. Maximum Gas Consumption is 181 CFM. Minmum Gas Pressure is 6 inches water column. Gas line inlet is 3/4". Inside volume is 27 cubic ft. Setting Space is 16 cubic ft. Inside Dimensions are 39"w x 34"d x 36"h. Uses 4-14" x 14" or 2-14" x 28" shelves per layer. Outside Dimensions are 54"w x 63"d x 65"h. Electronic flame safety, 100% Shut Off. Push button automatic spark ignition. Manual control valve. 0-15" water column pressure gauge. DD-1 digital, solid state, electronic controller which functions as a high-limit, on/off soaking controller. ETL (InterTek) Certified. Ship wt. is 2000 lbs.
Price: Price: Please call

 

Details 

Temperature Range is 0-2500F. 6 burners. 224,000 BTU. Maximum Gas Consumption is 203 CFM. Minmum Gas Pressure is 6 inches water column. Gas line inlet is 3/4". Inside volume is 31 cubic ft. Setting Space is 18 cubic ft. Inside Dimensions are 39"w x 34"d x 40"h. Uses 4-14" x 14" or 2-14" x 28" shelves per layer. Outside Dimensions are 54"w x 63"d x 70"h. Electronic flame safety, 100% Shut Off. Push button automatic spark ignition. Manual control valve. 0-15" water column pressure gauge. DD-1 digital, solid state, electronic controller which functions as a high-limit, on/off soaking controller. ETL (InterTek) Certified. Ship wt. is 2100 lbs.
Price: Price: Please call

 

Details 

Temperature Range is 0-2500F. 8 burners. 280,000 BTU. Maximum Gas Consumption is 254 CFM. Minmum Gas Pressure is 6 inches water column. Gas line inlet is 1". Inside volume is 35 cubic ft. Setting Space is 20 cubic ft. Inside Dimensions are 48"w x 30"d x 40"h. Uses 3-12" x 24" shelves per layer. Outside Dimensions are 63"w x 62"d x 70"h. Electronic flame safety, 100% Shut Off. Push button automatic spark ignition. Manual control valve. 0-15" water column pressure gauge. DD-1 digital, solid state, electronic controller which functions as a high-limit, on/off soaking controller. ETL (InterTek) Certified. Ship wt. is 2200 lbs.
Price: Price: Please call

 

Details 

Temperature Range is 0-2500F. 8 burners. 299,000 BTU. Maximum Gas Consumption is 271 CFM. Minmum Gas Pressure is 6 inches water column. Gas line inlet is 1". Inside volume is 40 cubic ft. Setting Space is 24 cubic ft. Inside Dimensions are 43"w x 38"d x 42"h. Uses 4-16" x 16" shelves per layer. Outside Dimensions are 58"w x 71"d x 72"h. Electronic flame safety, 100% Shut Off. Push button automatic spark ignition. Manual control valve. 0-15" water column pressure gauge. DD-1 digital, solid state, electronic controller which functions as a high-limit, on/off soaking controller. ETL (InterTek) Certified. Ship wt. is 2350 lbs.
Price: Price: Please call

 

Details 

Temperature Range is 0-2500F. 8 burners. 349,000 BTU. Maximum Gas Consumption is 317 CFM. Minmum Gas Pressure is 6 inches water column. Gas line inlet is 1". Inside volume is 45 cubic ft. Setting Space is 28 cubic ft. Inside Dimensions are 43"w x 38"d x 48"h. Uses 4-16" x 16" shelves per layer. Outside Dimensions are 58"w x 71"d x 78"h. Electronic flame safety, 100% Shut Off. Push button automatic spark ignition. Manual control valve. 0-15" water column pressure gauge. DD-1 digital, solid state, electronic controller which functions as a high-limit, on/off soaking controller. ETL (InterTek) Certified. Ship wt. is 2550 lbs.
Price: Price: Please call

 

Details 

Temperature Range is 0-2500F. 8 burners. 374,000 BTU. Maximum Gas Consumption is 340 CFM. Minmum Gas Pressure is 6 inches water column. Gas line inlet is 1". Inside volume is 47 cubic ft. Setting Space is 30 cubic ft. Inside Dimensions are 43"w x 38"d x 51"h. Uses 4-16" x 16" shelves per layer. Outside Dimensions are 58"w x 71"d x 81"h. Electronic flame safety, 100% Shut Off. Push button automatic spark ignition. Manual control valve. 0-15" water column pressure gauge. DD-1 digital, solid state, electronic controller which functions as a high-limit, on/off soaking controller. ETL (InterTek) Certified. Ship wt. is 2750 lbs.
Price: Price: Please call

 

Details 

Temperature Range is 0-2500F. 8 burners. 449,000 BTU. Maximum Gas Consumption is 408 CFM. Minmum Gas Pressure is 6 inches water column. Gas line inlet is 1". Inside volume is 56 cubic ft. Setting Space is 36 cubic ft. Inside Dimensions are 48"w x 42"d x 48"h. Uses 4-18" x 18" or 2-12" x 18" & 3-12" x 24" shelves per layer. Outside Dimensions are 60"w x 74"d x 78"h. Electronic flame safety, 100% Shut Off. Push button automatic spark ignition. Manual control valve. 0-15" water column pressure gauge. DD-1 digital, solid state, electronic controller which functions as a high-limit, on/off soaking controller. ETL (InterTek) Certified. Ship wt. is 3000 lbs.
Price: Price: Please call

 

Details 

Temperature Range is 0-2500F. 8 burners. 499,000 BTU. Maximum Gas Consumption is 453 CFM. Minmum Gas Pressure is 6 inches water column. Gas line inlet is 1". Inside volume is 60 cubic ft. Setting Space is 40 cubic ft. Inside Dimensions are 48"w x 42"d x 53"h. Uses 4-18" x 18" or 2-12" x 18" & 3-12" x 24" shelves per layer. Outside Dimensions are 60"w x 78"d x 80"h. Electronic flame safety, 100% Shut Off. Push button automatic spark ignition. Manual control valve. 0-15" water column pressure gauge. DD-1 digital, solid state, electronic controller which functions as a high-limit, on/off soaking controller. ETL (InterTek) Certified. Ship wt. is 3200 lbs.
Price: Price: Please call

 

Details 

Temperature Range is 0-2500F. 10 burners. 623,000 BTU. Maximum Gas Consumption is 566 CFM. Minmum Gas Pressure is 6 inches water column. Gas line inlet is 1-1/4". Inside volume is 67 cubic ft. Setting Space is 50 cubic ft. Inside Dimensions are 48"w x 42"d x 60"h. Uses 4-18" x 18" or 2-12" x 18" & 3-12" x 24" shelves per layer. Outside Dimensions are 60"w x 78"d x 88"h. Electronic flame safety, 100% Shut Off. Push button automatic spark ignition. Manual control valve. 0-15" water column pressure gauge. DD-1 digital, solid state, electronic controller which functions as a high-limit, on/off soaking controller. ETL (InterTek) Certified. Ship wt. is 3400 lbs.
Price: Price: Please call

 

Details 

Temperature Range is 0-2500F. 10 burners. 784,000 BTU. Maximum Gas Consumption is 680 CFM. Minmum Gas Pressure is 6 inches water column. Gas line inlet is 1-1/4". Inside volume is 96 cubic ft. Setting Space is 60 cubic ft. Inside Dimensions are 56"w x 46"d x 61"h. Uses 8-11" x 22" shelves per layer. Outside Dimensions are 75"w x 73"d x 88"h. Electronic flame safety, 100% Shut Off. Push button automatic spark ignition. Manual control valve. 0-15" water column pressure gauge. DD-1 digital, solid state, electronic controller which functions as a high-limit, on/off soaking controller. ETL (InterTek) Certified. Ship wt. is 3500 lbs.
Price: Price: Please call